©Endress+Hauser
-
Successor
-
For simple level measurement applications in liquids
-
More simplicity for your application
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Characteristic / Application
Characteristic / Application
-
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
-
-
Ambient temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
-
Process temperature
-40 °C...+150 °C
(-40 °F...+302 °F)
-
Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi)
-
-
Process connection
Thread:
NPT 1 1/2, R 1 1/2
Flange:
DN50...DN150,
ASME 2"...6",
JIS 10K
-
Process connection hygienic
Tri-Clamp ISO2852
DIN11864-1
DIN11851
-
-
Max. measurement distance
Max. measurement distance
-
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, TIIS, NEPSI
Overfill prevention WHG
SIL
EN10204-3.1
Marine GL/ABS/NK
-
Most downloaded
-
Micropilot M FMR230, 231
HART, PROFIBUS PA, FOUNDATION
Fieldbus
Description of Instrument Functions
English version - 07/2010
|
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
More
|
30/07/2010
|
|
|
|
03/08/2006
|
|
|
|
31/12/2005
|
|
|
|
22/12/2003
|
|
|
|
24/03/2003
|
|
|
|
Language:
|
English
|
Version:
|
30/07/2010
|
File size:
|
1.7 MB
|
File name:
|
BA221FEN_0310.pdf
|
135 documents
-
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
Technical Information
Continuous and non-contact level measurement.
Cost-effective 4 to 20 mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
01/10/2012
|
|
|
|
28/06/2011
|
|
|
|
31/01/2011
|
|
|
|
30/07/2010
|
|
|
|
17/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
01/10/2012
|
File size:
|
4.4 MB
|
File name:
|
TI00345FEN_1512.pdf
|
-
Micropilot M FMR230, 231
HART, PROFIBUS PA, FOUNDATION
Fieldbus
Description of Instrument Functions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
30/07/2010
|
|
|
|
03/08/2006
|
|
|
|
31/12/2005
|
|
|
|
22/12/2003
|
|
|
|
24/03/2003
|
|
|
|
Language:
|
English
|
Version:
|
30/07/2010
|
File size:
|
1.7 MB
|
File name:
|
BA221FEN_0310.pdf
|
-
Micropilot M FMR231
PROFIBUS PA
Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
31/08/2006
|
|
|
|
31/12/2005
|
|
|
|
25/10/2004
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
2.4 MB
|
File name:
|
BA00226FEN_1311.pdf
|
-
Micropilot M FMR231
FOUNDATION Fieldbus
Operating
Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
31/10/2008
|
|
|
|
30/06/2007
|
|
|
|
31/05/2006
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
3.1 MB
|
File name:
|
BA00229FEN_1311.pdf
|
-
Micropilot M FMR231
HART
Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
28/06/2011
|
|
|
|
30/07/2010
|
|
|
|
31/08/2006
|
|
|
|
01/12/2005
|
|
|
|
01/12/2003
|
|
|
|
Language:
|
English
|
Version:
|
28/06/2011
|
File size:
|
2.3 MB
|
File name:
|
BA00219FEN_1311.pdf
|
-
Exchange of antenna assembly on Micropilot M FMR231
Exchange of antenna assembly on Micropilot M FMR231
|
EN
|
|
Select other language
|
24/04/2012
|
|
|
|
Language:
|
English
|
Version:
|
24/04/2012
|
File size:
|
378.6 KB
|
File name:
|
KA00551FA2_0107.pdf
|
-
Micropilot M FMR231
Brief Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
31/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
31/12/2009
|
File size:
|
829.4 KB
|
File name:
|
KA1003FEN_1209.pdf
|
-
Micropilot M FMR231
Brief Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
31/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
31/12/2009
|
File size:
|
851.6 KB
|
File name:
|
KA1005FEN_1209.pdf
|
-
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
|
EN
|
|
Select other language
|
27/06/2007
|
|
|
|
31/05/2007
|
|
|
|
Language:
|
English
|
Version:
|
27/06/2007
|
File size:
|
235.5 KB
|
File name:
|
KA137Fa6_0607.pdf
|
-
Micropilot M, Leveflex M, Prosonic M - Modification of F12 housing (2
wire) for
connection of FHX40
Micropilot M, Leveflex M, Prosonic M - Modification of F12 housing (2
wire) for
connection of FHX40
|
EN
|
|
Select other language
|
20/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
20/04/2021
|
File size:
|
188.7 KB
|
File name:
|
KA00594F_A2.pdf
|
-
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
|
EN
|
|
Select other language
|
15/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
15/04/2021
|
File size:
|
532.2 KB
|
File name:
|
KA00512F00_A2.pdf
|
-
Micropilot M FMR231
Brief Operating Instructions
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
|
EN
|
|
Select other language
|
31/12/2009
|
|
|
|
Language:
|
English
|
Version:
|
31/12/2009
|
File size:
|
864.8 KB
|
File name:
|
KA1004FEN_1209.pdf
|
-
Micropilot II/M - exchange of housing T12
Micropilot II/M - exchange of housing T12
|
EN
|
|
Select other language
|
15/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
15/04/2021
|
File size:
|
172.5 KB
|
File name:
|
KA00557F00_A2.pdf
|
-
FMR2x, FMP4x, FMU4x - Exchange of terminal module
FMR2x, FMP4x, FMU4x - Exchange of terminal module
Language:
|
English
|
Version:
|
20/04/2021
|
File size:
|
196.1 KB
|
File name:
|
KA00580F_A2.pdf
|
-
Bedienungsanleitung/ Operating Instuction Micropilot M - Kurzanleitung.
Bedienungsanleitung/ Operating Instuction Micropilot M - Kurzanleitung.
|
EN
|
|
Select other language
|
01/12/2000
|
|
|
|
Language:
|
English
|
Version:
|
01/12/2000
|
File size:
|
103.9 KB
|
File name:
|
KA159FA2_0502.PDF
|
-
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
|
EN
|
|
Select other language
|
31/01/2018
|
|
|
|
Language:
|
English
|
Version:
|
31/01/2018
|
File size:
|
561.4 KB
|
File name:
|
EA01241FA2_0118.pdf
|
-
Cover F23
Installation instruction
Levelflex M, Micropilot M
|
EN
|
|
Select other language
|
12/04/2012
|
|
|
|
Language:
|
English
|
Version:
|
12/04/2012
|
File size:
|
346 KB
|
File name:
|
EA0025FA2_1009.pdf
|
-
Terminal module for housing F12/F23
Installation Instruction
Micropilot M, Levelflex M, Prosonic M
|
EN
|
|
Select other language
|
03/07/2013
|
|
|
|
Language:
|
English
|
Version:
|
03/07/2013
|
File size:
|
488.3 KB
|
File name:
|
EA01079FA2_0113.pdf
|
-
Safety Instructions
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA nL IIC T1...T6 Gc
GYJ14.1446X (NEPSI)
|
EN
|
|
Select other language
|
26/02/2015
|
|
|
|
Language:
|
English
|
Version:
|
26/02/2015
|
File size:
|
148.6 KB
|
File name:
|
XA01364FEN_0115.pdf
|
-
Safety Instructions
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
II 3 D Ex tc IIIC Txx°C Dc
EG 09 009
|
EN
|
|
Select other language
|
12/03/2014
|
|
|
|
01/07/2009
|
|
|
|
30/01/2006
|
|
|
|
Language:
|
English
|
Version:
|
12/03/2014
|
File size:
|
446.4 KB
|
File name:
|
XA00277FA3_1314.pdf
|
Search spare parts by number in drawing
30 spare parts & accessories
30 spare parts
30 accessories
-
Cover terminal compartment F12/F23,FHX40
Drawing number
Order code
11
52019062
-
-
Set of screws housing F12/T12/F23
Drawing number
Order code
12
535720-9020
-
Cover F12/T12 Alu, coated, gasket
Drawing number
Order code
20
517391-0011
-
Cover T3/T12 Alu, coated, gasket
Drawing number
Order code
25
518710-0020
-
Cover F12/T12 Alu, window, gasket
Drawing number
Order code
20
52005936
-
O-ring 113.9x3.63 EPDM, 5 pieces
-
Drawing number
Order code
11
52005643
-
Cover terminal compartment F12/F23
Drawing number
Order code
11
52006026
-
Terminal module 4-pole, HART, 2-wire
Drawing number
Order code
35
52006197
-
Terminal module 4-pole, PA, FF
Drawing number
Order code
35
52012156
-
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Drawing number
Order code
35
52013302
-
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
Drawing number
Order code
35
52013303
-
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
Drawing number
Order code
35
52018949
-
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
Drawing number
Order code
35
52018950
-
Drawing number
Order code
40
52026443
-
-
-
-
-
Adaption kit housing F12, 2-wire, FHX40
-
Tool for unplugging the antenna cable
-
HF-test cable 6GHz + resistor
-
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
-
-
-
Modification name plate, non Ex
-
-
Mounting bracket FHX40 1" / 2" pipe
-
Protective cover for housing T12/F12, SS
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .