Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Level measurement, capacitive. Application: liquids. Rod probe. Suitable for small vessels + heavy process conditions. :: High pressure / high temperature :: Suitable at heavy stress from side :: Longtime stable tightness
Fully/partly insulated rod probe with 3/4" Processconnection, suitable for heavy process condition T: Standard application E: European Certificate (EEx d, EEx ia)
Specialities
Interface measurement, Foam detection
Supply / Communication
HART PROFIBUS PA 3-wire PFM
Linearity error for conductive liquids
< 1% at 1m
Ambient temperature
Standard: -40 °C ... 70 °C With separate housing: -50°C ... 120 °C
Process temperature
-80 °C ... 200 °C
Process pressure / max. overpressure limit
Vacuum ... 25 bar
Main wetted parts
Insulation material: PTFE, PFA, PE 316L
Process connection
G 3/4A, G 1A /NPT 3/4", NPT 1" Flange ab DN25.../ASME 1".../JIS...
Notice the pressure and temperature derating. Notice for non conductive medium the DK.
Characteristic / Application
Fully/partly insulated rod probe with 3/4" Processconnection, suitable for heavy process condition T: Standard application E: European Certificate (EEx d, EEx ia)
Specialities
Interface measurement, Foam detection
Supply / Communication
3-wire PFM
Ambient temperature
Standard: -40 °C ... 70 °C With separate housing: -50°C ... 120 °C
Process temperature
-80 °C ... 200 °C
Process pressure / max. overpressure limit
Vacuum ... 25 bar
Main wetted parts
Insulation material: PTFE, PFA, PE 316L
Process connection
G 3/4A, G 1A /NPT 3/4", NPT 1" Flange from DN25.../ASME 1".../JIS...